// Copyright (C) Intel Corporation, 2011 - 2014 All Rights Reserved.
|
|
//
|
|
// File: UserConsentApi.cs
|
|
//
|
|
// Contents: Api code for Intel(R) Active Management Technology
|
|
// (Intel® AMT) User Consent.
|
|
//
|
|
// Notes: This sample application demonstrates various commands of user
|
|
// consent flow for AMT 6.1 and above FW versions.
|
|
//
|
|
//----------------------------------------------------------------------------
|
|
|
|
using System;
|
|
using Connection;
|
|
using Intel.Management.Wsman;
|
|
using System.Threading;
|
|
using System.Collections.Generic;
|
|
using Utils;
|
|
using Common.Utils;
|
|
|
|
|
|
namespace UserConsent
|
|
{
|
|
public class UserConsentApi : Connection_setup
|
|
{
|
|
#region ENUMS
|
|
|
|
/// <summary>
|
|
/// User input flags.
|
|
/// </summary>
|
|
public enum YesNoFlag
|
|
{
|
|
YES,
|
|
NO
|
|
};
|
|
|
|
/// <summary>
|
|
/// System power states.
|
|
/// </summary>
|
|
public enum PowerState
|
|
{
|
|
Other = 1,
|
|
On,
|
|
LightSleep,
|
|
DeepSleep,
|
|
SoftPowerCycle,
|
|
HardOff,
|
|
Hibernate,
|
|
SoftOff,
|
|
HardPowerCycle,
|
|
MasterBusReset,
|
|
DiagnosticInterrupt
|
|
};
|
|
|
|
/// <summary>
|
|
/// Indicates the state of OptIn (User Consent).
|
|
/// </summary>
|
|
public enum OptInState
|
|
{
|
|
/// <summary>
|
|
/// OptIn is required for sessions affected by OptInPolicy.
|
|
/// </summary>
|
|
NotStarted,
|
|
|
|
/// <summary>
|
|
/// A console has required an optIn code, but it was not displayed to the user yet.
|
|
/// </summary>
|
|
Requested,
|
|
|
|
/// <summary>
|
|
/// The optIn code was displayed to the user.
|
|
/// </summary>
|
|
Displayed,
|
|
|
|
/// <summary>
|
|
/// The optIn code was successfully entered by the IT.
|
|
/// </summary>
|
|
Received,
|
|
|
|
/// <summary>
|
|
/// Intel AMT had a KVM or Redirection open session.
|
|
/// </summary>
|
|
InSession
|
|
};
|
|
|
|
/// <summary>
|
|
/// Indicates the user consent policy.
|
|
/// </summary>
|
|
public enum OptInPolicy : uint
|
|
{
|
|
/// <summary>
|
|
/// The optIn is not required for any of the features.
|
|
/// </summary>
|
|
NONE,
|
|
|
|
/// <summary>
|
|
/// The optIn is required only for KVM.
|
|
/// </summary>
|
|
KVM,
|
|
|
|
/// <summary>
|
|
/// The optIn is required for all operations.
|
|
/// </summary>
|
|
ALL = UInt32.MaxValue
|
|
}
|
|
|
|
/// <summary>
|
|
/// Default screen values.
|
|
/// </summary>
|
|
public enum DefaultScreen
|
|
{
|
|
PrimaryScreen,
|
|
SecondaryScreen
|
|
//to do -- will need to include Third Screen option as well..
|
|
|
|
};
|
|
|
|
#endregion
|
|
|
|
#region CONSTANTS
|
|
|
|
private const uint MAX_NUMBER_OF_TRIALS = 3;
|
|
private const uint PT_STATUS_SUCCESS = 0;
|
|
private const uint PT_STATUS_UNSPECIFIED_ERROR = 2;
|
|
private const string STR_UNSPECIFIED_ERROR = "Requested operation is not allowed in Intel AMT system's current state.";
|
|
|
|
// OptInService Functions Statuses
|
|
Dictionary<uint, string> StatusCodes = new Dictionary<uint, string>()
|
|
{
|
|
{0, "PT_STATUS_SUCCESS"},
|
|
{1, "PT_STATUS_INTERNAL_ERROR"},
|
|
{2, "PT_STATUS_INVALID_STATE"},
|
|
{3, "PT_STATUS_BLOCKED"},
|
|
{2066, "PT_STATUS_INVALID_CREDENTIALS"}
|
|
};
|
|
|
|
// Yes No questions
|
|
private string ASK_FOR_SWITCH_SCREEN = "Would you like to switch monitors?";
|
|
private string ASK_FOR_SAMPLE_REBOOT = "Would you like to reboot the system?";
|
|
|
|
#endregion
|
|
|
|
#region PRIVATE_DATA_MEMBERS
|
|
|
|
public static CmdLineArguments Params = new CmdLineArguments();
|
|
IWsmanItem returnValue;
|
|
|
|
#endregion PRIVATE_DATA_MEMBERS
|
|
|
|
#region CONSTRUCTORS
|
|
// Creating the connection to the WSMan Client.
|
|
// Inheriting Connection details from Connection_setup class.
|
|
// Convert password to secure string to comply with wsman dll which supports passwords in SecureString
|
|
// format only.
|
|
public UserConsentApi(string ip, string username, string pwd, bool krb, MpsManager proxy, bool acceptSelfSignedCertificate = false)
|
|
: base(ip, username, pwd.ConvertToSecureString(), krb, proxy, acceptSelfSignedCertificate)
|
|
{
|
|
}
|
|
|
|
// Convert password to secure string to comply with wsman dll which supports passwords in SecureString
|
|
// format only.
|
|
public UserConsentApi(string ip, string username, string pwd, string clientCert, bool krb, MpsManager proxy, bool acceptSelfSignedCertificate = false)
|
|
: base(ip, username, pwd.ConvertToSecureString(), clientCert, krb, proxy, acceptSelfSignedCertificate)
|
|
{
|
|
}
|
|
|
|
#endregion CONSTRUCTORS
|
|
|
|
#region PUBLIC_FUNCTIONS
|
|
|
|
/// <summary>
|
|
/// Get user consent policy.
|
|
/// </summary>
|
|
/// <returns>The current policy</returns>
|
|
public OptInPolicy GetUserConsentPolicy()
|
|
{
|
|
// Get the IPS_OptInService using the Intel AMT as a reference.
|
|
IManagedReference optInServiceRef = wsmanClient.NewReference("SELECT * FROM IPS_OptInService WHERE Name='Intel(r) AMT OptIn Service'");
|
|
IManagedInstance optInServiceInstance = optInServiceRef.Get();
|
|
IWsmanItem optInRequired = optInServiceInstance.GetProperty("OptInRequired");
|
|
|
|
OptInPolicy policy = OptInPolicy.NONE;
|
|
|
|
// The optIn is not required for any of the features. (Property does not exist.)
|
|
if (optInRequired != null)//service.ContainsField("OptInRequired"))
|
|
{
|
|
// Indicates the OptIn (User Consent) Policy for Redirection operations,including KVM and IDER,
|
|
// or setting of boot options.
|
|
// This value is Read Only if the system was configured in Client Control Mode and Read-Write
|
|
// in Admin Control Mode and CanModifyOptInPolicy=true.
|
|
// The allowed values in Admin Control Mode are: None (opt-in not required for any of the features),
|
|
// KVM, or All (KVM+IDER+Boot options). Possible values in Client Control Mode: All.
|
|
policy = (OptInPolicy)(Convert.ToUInt64(optInRequired.ToString()));
|
|
}
|
|
return policy;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Get user consent state - mainly examines OptInState.
|
|
/// </summary>
|
|
/// <returns>The current state</returns>
|
|
public OptInState GetUserConsentState()
|
|
{
|
|
// Traversing the IPS_OptInService using the Intel AMT as a reference.
|
|
IManagedReference optInServiceRef = wsmanClient.NewReference("SELECT * FROM IPS_OptInService WHERE Name='Intel(r) AMT OptIn Service'");
|
|
IManagedInstance optInServiceInstance = optInServiceRef.Get();
|
|
IWsmanItem optInState = optInServiceInstance.GetProperty("OptInState");
|
|
|
|
// Return the optIn state as enum parameter.
|
|
OptInState state = (OptInState)(Convert.ToUInt64(optInState.ToString()));
|
|
|
|
return state;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Get the system power state.
|
|
/// </summary>
|
|
/// <returns>The current power state</returns>
|
|
public PowerState GetPowerState()
|
|
{
|
|
// Create a reference to the CIM_ComputerSystem instance.
|
|
IManagedReference computerSysRef = wsmanClient.NewReference("SELECT * FROM CIM_ComputerSystem WHERE Name='ManagedSystem'");
|
|
IManagedReference associatedPowerMgmtRef = wsmanClient.NewReference("CIM_AssociatedPowerManagementService");
|
|
associatedPowerMgmtRef.AddSelector("UserOfService", computerSysRef);
|
|
|
|
//Traverse to the CIM_AssociatedPowerManagementService instances that are connected to CIM_ComputerSystem instance.
|
|
int powerState;
|
|
foreach (IWsmanItem associatedPowerMgmtItem in associatedPowerMgmtRef.Enumerate("http://schemas.dmtf.org/wbem/wsman/1/wsman/SelectorFilter", null))
|
|
{
|
|
// For each instance, check if it is associated to the CIM_PowerManagementService instance.
|
|
if (associatedPowerMgmtItem.Object.GetProperty("ServiceProvided").IsA("CIM_PowerManagementService"))
|
|
{
|
|
IWsmanItem associatedPowerMgmtInstance = associatedPowerMgmtItem;
|
|
powerState = Convert.ToInt16(associatedPowerMgmtInstance.Object.GetProperty("PowerState").ToString());
|
|
return (PowerState)(powerState);
|
|
}
|
|
}
|
|
|
|
return 0;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Getting the user consent status.
|
|
/// </summary>
|
|
public IManagedInstance DisplayUserConsentStatus()
|
|
{
|
|
Console.WriteLine("Getting User Consent Status.");
|
|
|
|
IManagedReference optInServiceRef = wsmanClient.NewReference("SELECT * FROM IPS_OptInService WHERE Name='Intel(r) AMT OptIn Service'");
|
|
IManagedInstance optInServiceInstance = optInServiceRef.Get();
|
|
IWsmanItem optInRequired = optInServiceInstance.GetProperty("OptInRequired");
|
|
IWsmanItem optInState = optInServiceInstance.GetProperty("OptInState");
|
|
IWsmanItem optInDisplayTimeout = optInServiceInstance.GetProperty("OptInDisplayTimeout");
|
|
IWsmanItem optInCodeTimeout = optInServiceInstance.GetProperty("OptInCodeTimeout");
|
|
|
|
Console.WriteLine("User Consent Policy is: " + (OptInPolicy)(Convert.ToUInt64(optInRequired.ToString())));
|
|
Console.WriteLine("User Consent State is: " + (OptInState)(Convert.ToUInt64(optInState.ToString())));
|
|
Console.WriteLine("User Consent code Timeout is : " + optInCodeTimeout.ToString());
|
|
Console.WriteLine("User Consent Display Timeout is : " + optInDisplayTimeout.ToString());
|
|
|
|
return optInServiceInstance;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Request an optIn code. (Intel AMT generates code internally.)
|
|
/// </summary>
|
|
public void StartUserConsent()
|
|
{
|
|
Console.WriteLine("Starting User Consent Process...");
|
|
|
|
IManagedReference optInServiceRef = wsmanClient.NewReference("SELECT * FROM IPS_OptInService WHERE Name='Intel(r) AMT OptIn Service'");
|
|
IManagedInstance optInServiceInstance = optInServiceRef.Get();
|
|
IWsmanItem optInState = optInServiceInstance.GetProperty("OptInState");
|
|
|
|
if (optInState.ToString().Equals("0")) // OptInState = 0 ==> NotStarted
|
|
{
|
|
// Starting the user consent service.
|
|
// Intel AMT generates a random code and displays the consent form to the user.
|
|
IManagedInstance inputObject = optInServiceRef.CreateMethodInput("StartOptIn");
|
|
IManagedInstance outputObject = optInServiceRef.InvokeMethod(inputObject);
|
|
returnValue = outputObject.GetProperty("ReturnValue");
|
|
|
|
if (Convert.ToUInt64(returnValue.ToString()) != PT_STATUS_SUCCESS)
|
|
{
|
|
throw new Exception("Error occurred in StartUserConsent. Intel AMT status code: " + StatusCodes[Convert.ToUInt32(returnValue.ToString())]);
|
|
}
|
|
|
|
Params.MessageDisplay_Color("Success.", ConsoleColor.Green);
|
|
}
|
|
|
|
if (optInState.ToString().Equals("1")) // OptInState == 1 ==> Requested
|
|
{
|
|
Console.WriteLine("User Consent has been requested.");
|
|
}
|
|
|
|
if (optInState.ToString().Equals("3")) // OptInState == 3 ==> Received
|
|
{
|
|
Console.WriteLine("User Consent has been received.");
|
|
}
|
|
}
|
|
|
|
/// <summary>
|
|
/// Cancel a previous optIn code request.
|
|
/// </summary>
|
|
public void StopUserConsent()
|
|
{
|
|
Console.WriteLine("Canceling User Consent Process...");
|
|
|
|
// Getting the service instance.
|
|
IManagedReference optInServiceRef = wsmanClient.NewReference("SELECT * FROM IPS_OptInService WHERE Name='Intel(r) AMT OptIn Service'");
|
|
IManagedInstance inputObject = optInServiceRef.CreateMethodInput("CancelOptIn");
|
|
IManagedInstance outputObject = optInServiceRef.InvokeMethod(inputObject);
|
|
returnValue = outputObject.GetProperty("ReturnValue");
|
|
|
|
if (Convert.ToUInt64(returnValue.ToString()) != PT_STATUS_SUCCESS)
|
|
{
|
|
throw new Exception("Error occurred in StopUserConsent. Intel AMT status code: " + StatusCodes[Convert.ToUInt32(returnValue.ToString())]);
|
|
}
|
|
|
|
Params.MessageDisplay_Color("Success.", ConsoleColor.Green);
|
|
|
|
}
|
|
|
|
/// <summary>
|
|
/// Send the consent code to Intel AMT.
|
|
/// </summary>
|
|
public void SendConsentCode()
|
|
{
|
|
// Count the number of trials to send the consent code.
|
|
uint codeTrials = 0;
|
|
|
|
while (codeTrials != MAX_NUMBER_OF_TRIALS)
|
|
{
|
|
uint optInCode;
|
|
|
|
// Asking for user consent code to send - waiting for input.
|
|
Console.WriteLine("Please enter user consent code:");
|
|
string strCode = Console.ReadLine();
|
|
|
|
// Parsing the user input to uint code (validate the input).
|
|
uint.TryParse(strCode, out optInCode);
|
|
|
|
if (optInCode != 0 || uint.Parse(strCode) == 0)
|
|
{
|
|
// When caller exceeded the number of allowed SendConsent retries, there is no indication that the
|
|
// state machine has reset. Therefore we are checking the OptInState, after each SendConsent failure,
|
|
// to figure out if it can send an additional retry.
|
|
|
|
// Getting the service instance for getting the user consent state.
|
|
IManagedReference optInServiceRef = wsmanClient.NewReference("SELECT * FROM IPS_OptInService WHERE Name='Intel(r) AMT OptIn Service'");
|
|
IManagedInstance optInServiceInstance = optInServiceRef.Get();
|
|
IWsmanItem OptIn_state = optInServiceInstance.GetProperty("OptInState");
|
|
|
|
if (OptIn_state.ToString().Equals("2")) // OptInState = 2 ==>Displayed
|
|
{
|
|
Console.WriteLine("Sending Consent Code.. ");
|
|
|
|
IManagedInstance inputObject = optInServiceRef.CreateMethodInput("SendOptInCode");
|
|
inputObject.SetProperty("OptInCode", optInCode.ToString());
|
|
IManagedInstance outputObject = optInServiceRef.InvokeMethod(inputObject);
|
|
returnValue = outputObject.GetProperty("ReturnValue");
|
|
|
|
if (Convert.ToUInt64(returnValue.ToString()) != PT_STATUS_SUCCESS)
|
|
{
|
|
Params.MessageDisplay_Color("Failed to send user consent code. Try again.", ConsoleColor.Red);
|
|
codeTrials++;
|
|
}
|
|
else
|
|
{
|
|
Params.MessageDisplay_Color("Success.", ConsoleColor.Green);
|
|
break;
|
|
}
|
|
}
|
|
}
|
|
|
|
else
|
|
{
|
|
throw new InvalidCastException("An illegal value was entered. Please provide a valid Code(six digits).");
|
|
}
|
|
}
|
|
|
|
if (Convert.ToUInt64(returnValue.ToString()) != PT_STATUS_SUCCESS)
|
|
{
|
|
Params.MessageDisplay_Color("Maximal number of trials was reached - code is expired.", ConsoleColor.Red);
|
|
throw new Exception("Error occurred in SendConsentCode. Intel AMT status code: " + StatusCodes[Convert.ToUInt32(returnValue.ToString())]);
|
|
}
|
|
}
|
|
|
|
/// <summary>
|
|
/// Change the default monitor.
|
|
/// </summary>
|
|
public void SetDefaultMonitor()
|
|
{
|
|
Console.WriteLine("Setting Default Monitor...");
|
|
|
|
uint value;
|
|
IManagedReference secIOServiceRef = wsmanClient.NewReference("SELECT * FROM IPS_SecIOService WHERE Name='SecIO'");
|
|
IManagedInstance secIOServiceInstance = secIOServiceRef.Get();
|
|
value = uint.Parse(secIOServiceInstance.GetProperty("DefaultScreen").ToString());
|
|
|
|
if (value == 0)
|
|
{
|
|
secIOServiceInstance.SetProperty("DefaultScreen", "1");
|
|
}
|
|
else
|
|
{
|
|
// Starting with Release 8.0, Intel AMT supports up to three screens, so the value can be 0, 1, or 2.
|
|
if (UtilitiesMethods.GetCoreVersion(wsmanClient).CompareTo("8.0.0.0") >= 0)
|
|
{
|
|
if (value == 1)
|
|
secIOServiceInstance.SetProperty("DefaultScreen", "2");
|
|
if (value == 2)
|
|
secIOServiceInstance.SetProperty("DefaultScreen", "0");
|
|
}
|
|
else
|
|
{
|
|
secIOServiceInstance.SetProperty("DefaultScreen", "0");
|
|
}
|
|
}
|
|
|
|
secIOServiceRef.Put(secIOServiceInstance);
|
|
Params.MessageDisplay_Color("Success.", ConsoleColor.Green);
|
|
}
|
|
|
|
/// <summary>
|
|
/// Gets the current default monitor.
|
|
/// </summary>
|
|
public void GetDefaultMonitor()
|
|
{
|
|
IManagedReference secIOServiceRef = wsmanClient.NewReference("SELECT * FROM IPS_SecIOService WHERE Name='SecIO'");
|
|
IManagedInstance secIOServiceInstance = secIOServiceRef.Get();
|
|
Console.WriteLine("The current default monitor: " + secIOServiceInstance.GetProperty("DefaultScreen").ToString());
|
|
}
|
|
|
|
/// <summary>
|
|
/// Run full user consent flow.
|
|
/// See the attached diagram (UserConsentFlowDiagram.bmp) that depicts the flow performed by the full user consent flow option.
|
|
/// </summary>
|
|
public void RunFullUserConsentFlow()
|
|
{
|
|
// -------------------------------------
|
|
// STEP 1: Check the system power state.
|
|
// -------------------------------------
|
|
if (GetPowerState() != (PowerState.On))
|
|
{
|
|
// If system state is Sx - close the program.
|
|
Params.MessageDisplay_Color("This flow does not support the current power state.", ConsoleColor.Red);
|
|
return;
|
|
}
|
|
|
|
// -------------------------------------
|
|
// STEP 2: Check the user consent state.
|
|
// -------------------------------------
|
|
DisplayUserConsentStatus();
|
|
|
|
// Check the system policy:
|
|
// Policy is "NONE" - indicates that user consent is not required.
|
|
if (GetUserConsentPolicy() == OptInPolicy.NONE)
|
|
{
|
|
Params.MessageDisplay_Color("User consent is not required for any operation", ConsoleColor.Yellow);
|
|
return;
|
|
}
|
|
|
|
// Get user consent state.
|
|
OptInState state = GetUserConsentState();
|
|
|
|
// Check the system state:
|
|
if (state != OptInState.NotStarted)
|
|
{
|
|
// The state is received - the code was entered successfully by the IT.
|
|
if (state == OptInState.Received)
|
|
{
|
|
Params.MessageDisplay_Color("User consent was already obtained.", ConsoleColor.Yellow);
|
|
return;
|
|
}
|
|
if (state == OptInState.InSession)
|
|
{
|
|
Params.MessageDisplay_Color("User Consent is not required. KVM or Redirection session is currently opened.", ConsoleColor.Yellow);
|
|
return;
|
|
}
|
|
// The state should be displayed (The code was displayed to the user), or requested (The console required an opt-in code)
|
|
else
|
|
{
|
|
string errorMessage = "Full flow cannot be executed in the current user-consent state. Resetting the state using cancel option.";
|
|
|
|
Params.MessageDisplay_Color(errorMessage, ConsoleColor.Yellow);
|
|
|
|
// Cancel the user consent (reset OptInState to "NotStarted").
|
|
StopUserConsent();
|
|
}
|
|
}
|
|
|
|
// ------- -------------------------------
|
|
// STEP 3: Start the user consent process.
|
|
// ---------------------------------------
|
|
StartUserConsent();
|
|
|
|
// The "Requested" state is ambiguous. SW cannot determine, based on this state alone, whether it should
|
|
// initiate a reboot to display MEBx code, or keep waiting for Intel AMT to display Sprite screen.
|
|
// A "Requested" state indicates to SW that a reboot is required for MEBx only after 15 seconds from StartConsent()
|
|
// The Sleep of 15 seconds (15000 milliseconds) is required since Intel AMT FW will only determine
|
|
// if it can use Sprite screen after a few seconds.
|
|
Thread.Sleep(15000);
|
|
|
|
// ---------------------------
|
|
// STEP 4: Display the Sprite.
|
|
// ---------------------------
|
|
// Intel AMT FW detects whether integrated gfx can be used for consent and prioritizes it over MEBx method.
|
|
// If the state is not "Displayed" - indicates that Discrete gfx are present in the platform
|
|
// and displays the sprite over MEBx.
|
|
// Check user consent state.
|
|
if (GetUserConsentState() != OptInState.Displayed)
|
|
{
|
|
Console.WriteLine("User Consent form will be displayed via MEBx.");
|
|
if ((YesNoFlag)Params.AskYesNo(ASK_FOR_SAMPLE_REBOOT) == YesNoFlag.YES)
|
|
{
|
|
BootSystem(PowerState.SoftPowerCycle);
|
|
}
|
|
}
|
|
|
|
// The DefaultScreen property controls on which screen the Sprite message is displayed.
|
|
// It is used by the IT to switch between screens if the local user does not see the Consent form.
|
|
if ((YesNoFlag)Params.AskYesNo(ASK_FOR_SWITCH_SCREEN) == YesNoFlag.YES)
|
|
{
|
|
SetDefaultMonitor();
|
|
}
|
|
|
|
// -----------------------------
|
|
// STEP 5: Send the consent code.
|
|
// ------------------------------
|
|
// Get the user consent code and send it.
|
|
SendConsentCode();
|
|
|
|
//Perform the task that required user consent...!
|
|
|
|
//Stop the Consent Flow
|
|
StopUserConsent();
|
|
}
|
|
|
|
#endregion
|
|
|
|
#region UTILS_FUNCTIONS
|
|
|
|
/// <summary>
|
|
/// Reboot the system.
|
|
/// </summary>
|
|
public void BootSystem(PowerState requestedPower)
|
|
{
|
|
Console.WriteLine("Booting the system... ");
|
|
|
|
IManagedReference powerManagementRef = wsmanClient.NewReference("SELECT * FROM CIM_PowerManagementService WHERE Name='Intel(r) AMT Power Management Service'");
|
|
IManagedInstance inputObject = powerManagementRef.CreateMethodInput("RequestPowerStateChange");
|
|
inputObject.SetProperty("PowerState", (uint)requestedPower); // 5 = SoftPowerCycle - other options can also be set, based on the value that is being passed.
|
|
/*
|
|
* The supported PowerState values are:
|
|
* 2 (Power Up), 5 (Power Cycle), 8 (Power Down), 10 (Master Bus Reset)
|
|
*
|
|
* ValueMap={2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16}
|
|
Values={Power On, Sleep - Light, Sleep - Deep, Power Cycle (Off Soft), Power Off - Hard, Hibernate, Power Off - Soft,
|
|
* Power Cycle (Off Hard), Master Bus Reset, Diagnostic Interrupt (NMI), Power Off - Soft Graceful, Power Off - Hard Graceful,
|
|
* Master Bus Reset Graceful, Power Cycle (Off - Soft Graceful), Power Cycle (Off - Hard Graceful)}
|
|
*/
|
|
|
|
IManagedReference computerSystemRef = wsmanClient.NewReference("SELECT * FROM CIM_ComputerSystem WHERE Name='ManagedSystem'");
|
|
inputObject.SetProperty("ManagedElement", computerSystemRef);
|
|
IManagedInstance outputObject = powerManagementRef.InvokeMethod(inputObject);
|
|
IWsmanItem return_value = outputObject.GetProperty("ReturnValue");
|
|
|
|
if (Convert.ToUInt64(return_value.ToString()) != PT_STATUS_SUCCESS)
|
|
{
|
|
throw new Exception("Failed to change power state. Intel AMT status code: " + StatusCodes[Convert.ToUInt32(return_value.ToString())]);
|
|
}
|
|
|
|
}
|
|
#endregion
|
|
}
|
|
}
|