// Copyright (c) Intel Corporation, 2011 - 2012 All Rights Reserved.
|
|
//
|
|
// File: PowerPackageApi.cs
|
|
//
|
|
// Contents: Api code for Intel(R) Active Management Technology
|
|
// (Intel® AMT) PowerPackage Sample.
|
|
//
|
|
// Notes: This sample demonstrates how to how to use various commands of
|
|
// the PowerPackage service.
|
|
//
|
|
//----------------------------------------------------------------------------
|
|
using System;
|
|
using System.Collections.Generic;
|
|
using Utils;
|
|
using Intel.Management.Wsman;
|
|
using Common.Utils;
|
|
|
|
namespace PowerPackage
|
|
{
|
|
public class PowerPackageApi : Connection.Connection_setup
|
|
{
|
|
#region PRIVATE_DATA_MEMBERS
|
|
|
|
/// <summary>
|
|
/// Indicate whether G3 support is on or off
|
|
/// </summary>
|
|
private enum ON_OFF_FLAG
|
|
{
|
|
ON,
|
|
OFF
|
|
};
|
|
|
|
/// <summary>
|
|
/// The current power state of the Intel AMT system. Also needed for querying allowed
|
|
/// power transitions.
|
|
/// </summary>
|
|
public enum PowerState
|
|
{
|
|
/// <summary>
|
|
/// Power state could not be determined, perhaps due to network error.
|
|
/// </summary>
|
|
Unknown = 0,
|
|
|
|
/// <summary>
|
|
/// The system is powered on (S0).
|
|
/// </summary>
|
|
On,
|
|
/// <summary>
|
|
/// Alias for On.
|
|
/// </summary>
|
|
S0 = On,
|
|
|
|
/// <summary>
|
|
/// The system is in standby mode (S3).
|
|
/// </summary>
|
|
StandBy,
|
|
|
|
/// <summary>
|
|
/// Alias for standby.
|
|
/// </summary>
|
|
S3 = StandBy,
|
|
|
|
/// <summary>
|
|
/// The system is in hibernate mode (S4).
|
|
/// </summary>
|
|
Hibernate,
|
|
|
|
/// <summary>
|
|
/// Alias for Hibernate.
|
|
/// </summary>
|
|
S4 = Hibernate,
|
|
|
|
/// <summary>
|
|
/// The system is powered off (S5).
|
|
/// </summary>
|
|
Off,
|
|
|
|
/// <summary>
|
|
/// Alias for Off.
|
|
/// </summary>
|
|
S5 = Off,
|
|
|
|
/// <summary>
|
|
/// Error value.
|
|
/// </summary>
|
|
Unexpected
|
|
}
|
|
|
|
/* /// <summary>
|
|
/// Index power state table to indicate the various power states
|
|
/// </summary>
|
|
private static PowerState[] table =
|
|
{
|
|
PowerState.Unknown, // <-- real unknown; rest are defensive coding
|
|
PowerState.Unexpected, // Other,
|
|
PowerState.On, // regular on
|
|
PowerState.On, // LightSleep,
|
|
PowerState.StandBy, // DeepSleep,
|
|
PowerState.Unexpected, // not supported in code
|
|
PowerState.Unexpected, // HardOff,
|
|
PowerState.Hibernate,
|
|
PowerState.Off,
|
|
PowerState.Unexpected, // HardPowerCycle,
|
|
PowerState.Unexpected, // MasterBusReset,
|
|
PowerState.Unexpected, // DiagnosticInterrupt,
|
|
};
|
|
*/
|
|
|
|
// const that identify the given CLI arguments
|
|
private const uint OnInS0_Only = 1;
|
|
private const uint OnInSx_AC = 2;
|
|
|
|
/// <summary>
|
|
/// Power schema in S0 only, mobile and desktop.
|
|
/// </summary>
|
|
private const string POWER_PACKAGE_MOBILE_ON_S0 = "djmXEQtWUEOIcJgS85G1YA==";
|
|
private const string POWER_PACKAGE_DESKTOP_ON_S0 = "lE+DEvsQT9yWjh4jKwyQZQ==";
|
|
|
|
/// <summary>
|
|
///Power schema in Sx, mobile and desktop.
|
|
/// </summary>
|
|
private const string POWER_PACKAGE_DESKTOP_ON_S0_SX_5 = "cyJzRiPcQy+pihPTeYLYVQ==";
|
|
private const string POWER_PACKAGE_MOBILE_ON_S0_SX_5 = "MIAN7gnAeEOvKHhootu+Og==";
|
|
private const string POWER_PACKAGE_DESKTOP_ON_S0_SX_3 = "coarrJa0SOKbnpt9+Rx/1A==";
|
|
private const string POWER_PACKAGE_MOBILE_ON_S0_SX_3 = "Uw4I22wP2Uiy0olY0/EVbg==";
|
|
|
|
/// <summary>
|
|
/// Power schema in Sx when G3 support is On.
|
|
/// </summary>
|
|
private const string POWER_PACKAGE_DISABLE_WAKE_AFTER_POWER_LOSS_7 = "1gvj7QTFLEa3ctGAGO4vxA==";
|
|
private const string POWER_PACKAGE_DISABLE_WAKE_AFTER_POWER_LOSS_6 = "xRmkum5vjU2yJ1F/fkWV2w==";
|
|
|
|
private Dictionary<string, uint> _priorityMapS0;
|
|
|
|
private Dictionary<string, uint> _priorityMapSxOnAfterPowerLossPreferWlan;
|
|
private Dictionary<string, uint> _priorityMapSxOnAfterPowerLossDisableWlan;
|
|
private Dictionary<string, uint> _priorityMapSxOffAfterPowerLossPreferWlan;
|
|
private Dictionary<string, uint> _priorityMapSxOffAfterPowerLossDisableWlan;
|
|
|
|
// This collection will apply to Intel AMT 4.0 and >= 6.0.
|
|
private Dictionary<string, uint> _priorityMapSxGeneral;
|
|
|
|
// User parameters
|
|
private static CmdLineArguments Params = new CmdLineArguments();
|
|
|
|
#endregion PRIVATE_DATA_MEMBERS
|
|
|
|
#region CONSTRUCTORS
|
|
|
|
/// <summary>
|
|
/// Constructor.
|
|
/// </summary>
|
|
/// <param name="wsmanClient">IWSManClient, the wsmanClient object</param>
|
|
/// Inheriting Connection details from Connection_setup class.
|
|
// Convert password to secure string to comply with wsman dll which supports passwords in SecureString
|
|
// format only.
|
|
public PowerPackageApi(string ip, string username, string pwd, bool krb, MpsManager proxy, bool acceptSelfSignedCertificate = false)
|
|
: base(ip, username, pwd.ConvertToSecureString(), krb, proxy, acceptSelfSignedCertificate)
|
|
{
|
|
InitPriorityMap();
|
|
}
|
|
|
|
public PowerPackageApi(string ip, string username, string pwd, string secure, bool krb, MpsManager proxy, bool acceptSelfSignedCertificate = false)
|
|
: base(ip, username, pwd.ConvertToSecureString(), secure, krb, proxy, acceptSelfSignedCertificate)
|
|
{
|
|
InitPriorityMap();
|
|
}
|
|
|
|
#endregion CONSTRUCTORS
|
|
|
|
#region PRIVATE_FUNCTIONS
|
|
|
|
/// <summary>
|
|
/// Initialize the power package priority map
|
|
/// according to recommended settings.
|
|
/// </summary>
|
|
private void InitPriorityMap()
|
|
{
|
|
_priorityMapS0 = new Dictionary<string, uint>();
|
|
_priorityMapSxOnAfterPowerLossPreferWlan = new Dictionary<string, uint>();
|
|
_priorityMapSxOnAfterPowerLossDisableWlan = new Dictionary<string, uint>();
|
|
_priorityMapSxOffAfterPowerLossPreferWlan = new Dictionary<string, uint>();
|
|
_priorityMapSxOffAfterPowerLossDisableWlan = new Dictionary<string, uint>();
|
|
_priorityMapSxGeneral = new Dictionary<string, uint>();
|
|
|
|
// power packages available for S0
|
|
_priorityMapS0.Add(POWER_PACKAGE_MOBILE_ON_S0, 1);
|
|
_priorityMapS0.Add(POWER_PACKAGE_DESKTOP_ON_S0, 2);
|
|
|
|
// sorted power package for Sx based on priority (4.0 and >= 6.0)
|
|
_priorityMapSxGeneral.Add(POWER_PACKAGE_DESKTOP_ON_S0_SX_5, 1);
|
|
_priorityMapSxGeneral.Add(POWER_PACKAGE_MOBILE_ON_S0_SX_5, 2);
|
|
_priorityMapSxGeneral.Add(POWER_PACKAGE_DESKTOP_ON_S0_SX_3, 3);
|
|
_priorityMapSxGeneral.Add(POWER_PACKAGE_MOBILE_ON_S0_SX_3, 4);
|
|
|
|
// sorted power package for Sx based on priority (POWER_LOSS=ON, PreferWake)
|
|
_priorityMapSxOnAfterPowerLossPreferWlan.Add(POWER_PACKAGE_DESKTOP_ON_S0_SX_5, 1);
|
|
_priorityMapSxOnAfterPowerLossPreferWlan.Add(POWER_PACKAGE_DESKTOP_ON_S0_SX_3, 2);
|
|
|
|
// sorted power package for Sx based on priority (POWER_LOSS=ON, DisableWake)
|
|
_priorityMapSxOnAfterPowerLossDisableWlan.Add(POWER_PACKAGE_DESKTOP_ON_S0_SX_3, 1);
|
|
|
|
// sorted power package for Sx based on priority (POWER_LOSS=OFF, PreferWake)
|
|
_priorityMapSxOffAfterPowerLossPreferWlan.Add(POWER_PACKAGE_DISABLE_WAKE_AFTER_POWER_LOSS_7, 1);
|
|
_priorityMapSxOffAfterPowerLossPreferWlan.Add(POWER_PACKAGE_DISABLE_WAKE_AFTER_POWER_LOSS_6, 2);
|
|
|
|
// sorted power package for Sx based on priority (POWER_LOSS=OFF, Disable)
|
|
_priorityMapSxOffAfterPowerLossDisableWlan.Add(POWER_PACKAGE_DISABLE_WAKE_AFTER_POWER_LOSS_6, 2);
|
|
}
|
|
|
|
///<summary>
|
|
///Get System Power State
|
|
///</summary>
|
|
///<param name="state"> out param contains the current power state.</param>
|
|
public PowerState GetSystemPowerState()
|
|
{
|
|
IManagedReference computerSystemRef = wsmanClient.NewReference("SELECT * FROM CIM_ComputerSystem WHERE Name='ManagedSystem'");
|
|
IManagedReference associatedPowerManagementRef = wsmanClient.NewReference("CIM_AssociatedPowerManagementService");
|
|
|
|
associatedPowerManagementRef.AddSelector("UserOfService", computerSystemRef);
|
|
foreach (IWsmanItem associatedPowerMgmtItem in associatedPowerManagementRef.Enumerate("http://schemas.dmtf.org/wbem/wsman/1/wsman/SelectorFilter", null))
|
|
{
|
|
//for each instance,check if it is associated to the CIM_powerManagmentService instance.
|
|
if (associatedPowerMgmtItem.Object.GetProperty("ServiceProvided").IsA("CIM_PowerManagementService"))
|
|
{
|
|
IWsmanItem associatedPowerMgmtInstance = associatedPowerMgmtItem;
|
|
PowerState powerState = (PowerState)Enum.Parse(typeof(PowerState), (associatedPowerMgmtInstance.Object.GetProperty("PowerState").ToString()));
|
|
return powerState;
|
|
}
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
/// <summary>
|
|
/// This function will enumerate the AMT_SystemPowerScheme in order to get the available power schemas
|
|
/// and then it will try to set the power package based on the params given.
|
|
/// For example:
|
|
/// Giving priorityMap of Sx will try to set power package 5
|
|
/// if it is available, otherwise it will try to set power package 3.
|
|
///
|
|
/// Giving priorityMap of G3 Support will try to set power package 7
|
|
/// if it is available, otherwise it will try to set power package 6 if available.
|
|
/// </summary>
|
|
/// <param name="priorityMap">dictionary which contains the potential power packages</param>
|
|
private void SetPPBasedOnPriority(Dictionary<string, uint> priorityMap)
|
|
{
|
|
|
|
// Sorted list which will contain power packages
|
|
// that exist to the remote machine, sorted according
|
|
// to the recommended priority
|
|
|
|
SortedList<uint, IManagedReference> existingScheme = new SortedList<uint, IManagedReference>();
|
|
|
|
// Traversing the AMT_SystemPowerScheme instances using the Intel AMT instance as EPR.
|
|
IManagedReference computerSystemRef = wsmanClient.NewReference("SELECT * FROM CIM_ComputerSystem WHERE Name='Intel(r) AMT'");
|
|
IManagedReference elementSettingsDataRef = wsmanClient.NewReference("CIM_ElementSettingData");
|
|
elementSettingsDataRef.AddSelector("ManagedElement", computerSystemRef);
|
|
|
|
//Traverse to the CIM_ElementSettingData instances that are connected to CIM_ComputerSystem.
|
|
foreach (IWsmanItem elementSettingDataItem in elementSettingsDataRef.Enumerate("http://schemas.dmtf.org/wbem/wsman/1/wsman/SelectorFilter", null))
|
|
{
|
|
//For each instance, check if it is associated to the AMT_SystemPowerScheme instance.
|
|
if (elementSettingDataItem.Object.GetProperty("SettingData").IsA("AMT_SystemPowerScheme"))
|
|
{
|
|
//Get the AMT_systemPowerScheme object using its EPR.
|
|
IManagedInstance systemPowerSchemeInstance = elementSettingDataItem.Object.GetProperty("SettingData").Ref.Get();
|
|
IWsmanItem schemeGUID = systemPowerSchemeInstance.GetProperty("SchemeGUID");
|
|
|
|
if (priorityMap.ContainsKey(schemeGUID.ToString()))
|
|
{
|
|
existingScheme.Add(priorityMap[schemeGUID.ToString()], elementSettingDataItem.Object.GetProperty("SettingData").Ref);
|
|
}
|
|
}
|
|
}
|
|
|
|
// TODO: Ask Nati - how exactly to implement..!
|
|
bool succeeded = false;
|
|
foreach (KeyValuePair<uint, IManagedReference> item in existingScheme)
|
|
{
|
|
try
|
|
{
|
|
IManagedReference computerSystemRef1 = wsmanClient.NewReference("SELECT * FROM CIM_ComputerSystem WHERE Name='Intel(r) AMT'");
|
|
IManagedReference elementSettingDataRef = wsmanClient.NewReference("CIM_ElementSettingData");
|
|
|
|
elementSettingDataRef.AddSelector("ManagedElement", computerSystemRef1);
|
|
|
|
//Traverse to the CIM_ElementSettingData instances that are connected to CIM_ComputerSystem.
|
|
|
|
foreach (IWsmanItem elementSettingDataItem in elementSettingDataRef.Enumerate("http://schemas.dmtf.org/wbem/wsman/1/wsman/SelectorFilter", null))
|
|
{
|
|
//For each instance, check if it is associated to the AMT_SystemPowerScheme instance.
|
|
if (elementSettingDataItem.Object.GetProperty("SettingData").IsA("AMT_SystemPowerScheme"))
|
|
{
|
|
// Get the AMT_systemPowerScheme object using its EPR.
|
|
IManagedReference systemPowerSchemeRef = elementSettingDataItem.Object.GetProperty("SettingData").Ref;
|
|
|
|
IManagedInstance systemPowerSchemeInstance = systemPowerSchemeRef.Get();
|
|
|
|
IManagedInstance inputObject = systemPowerSchemeRef.CreateMethodInput("SetPowerScheme");
|
|
IManagedInstance outputObject = systemPowerSchemeRef.InvokeMethod(inputObject);
|
|
IWsmanItem returnValue = outputObject.GetProperty("ReturnValue");
|
|
|
|
if (returnValue.ToString().CompareTo("0") == 0)
|
|
{
|
|
Console.WriteLine("Instance ID: {0}", systemPowerSchemeInstance.GetProperty("InstanceID").ToString());
|
|
Console.WriteLine("Description: {0}", systemPowerSchemeInstance.GetProperty("Description").ToString());
|
|
Console.WriteLine("GUID: {0}\n", systemPowerSchemeInstance.GetProperty("SchemeGUID").ToString());
|
|
succeeded = true;
|
|
break;
|
|
|
|
}
|
|
}
|
|
}
|
|
}
|
|
catch (Exception e)
|
|
{
|
|
Params.catchType(e, e.Message);
|
|
}
|
|
|
|
if (!succeeded)
|
|
{
|
|
Console.WriteLine("Failed to set power package\n");
|
|
}
|
|
}
|
|
}
|
|
|
|
/// <summary>
|
|
/// Based on afterPowerLoss and wakeOn params, sets the relevant set of power packages to try
|
|
/// </summary>
|
|
/// <param name="afterPowerLoss">On - load machine after power loss to S0; Off - after power loss machine will not be reachable</param>
|
|
/// <param name="wakeOn">prefer wake on power package</param>
|
|
/// <returns>set of power packages sorted according to the priority</returns>
|
|
private Dictionary<string, uint> SetPriorityMapSx(ON_OFF_FLAG afterPowerLoss, ON_OFF_FLAG wakeOn)
|
|
{
|
|
Dictionary<string, uint> v;
|
|
if (afterPowerLoss == ON_OFF_FLAG.ON)
|
|
{
|
|
if (wakeOn == ON_OFF_FLAG.ON)
|
|
{
|
|
v = _priorityMapSxOnAfterPowerLossPreferWlan;
|
|
}
|
|
else
|
|
{
|
|
v = _priorityMapSxOnAfterPowerLossDisableWlan;
|
|
}
|
|
}
|
|
else
|
|
{
|
|
if (wakeOn == ON_OFF_FLAG.ON)
|
|
{
|
|
v = _priorityMapSxOffAfterPowerLossPreferWlan;
|
|
}
|
|
else
|
|
{
|
|
v = _priorityMapSxOffAfterPowerLossDisableWlan;
|
|
}
|
|
}
|
|
return v;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Set power package On in S0.
|
|
/// </summary>
|
|
private void SetPPOnInS0()
|
|
{
|
|
Console.WriteLine("---------------Set Power Package S0--------------");
|
|
SetPPBasedOnPriority(_priorityMapS0);
|
|
|
|
}
|
|
|
|
/// <summary>
|
|
/// Ask the user if there is a need to continue the flow of changing the power schema.
|
|
/// </summary>
|
|
/// <returns>yes = continue the flow, no = exit the flow</returns>
|
|
private string continueFlow()
|
|
{
|
|
string chosenOption = string.Empty;
|
|
do
|
|
{
|
|
Console.WriteLine("Are you sure you want to continue[yes, no]?");
|
|
chosenOption = Console.ReadLine();
|
|
if (chosenOption == string.Empty)
|
|
chosenOption = "no";
|
|
else
|
|
chosenOption = chosenOption.ToLower();
|
|
|
|
if (chosenOption.Equals("yes") || chosenOption.Equals("no"))
|
|
break;
|
|
|
|
} while (true);
|
|
|
|
return chosenOption;
|
|
}
|
|
|
|
#endregion
|
|
|
|
#region PUBLIC_FUNCTION
|
|
|
|
/// <summary>
|
|
/// Defines the minimum time value, in minutes, that
|
|
/// Intel AMT will be operable after waking up from a
|
|
/// sleep power state. This timer value will be reloaded
|
|
/// whenever Intel AMT is servicing requests. Note: this
|
|
/// setting may not be applicable under some power package
|
|
/// definitions
|
|
/// </summary>
|
|
/// <param name="value">the actual idleWakeTimeout value</param>
|
|
public void setIdleWakeTimeout(uint value)
|
|
{
|
|
Console.WriteLine("---------------Set Idle Wake Timeout--------------");
|
|
|
|
// Traversing the AMT_GeneralSettings instance using the Intel AMT as a reference.
|
|
|
|
IManagedReference generalSettingsRef = wsmanClient.NewReference("SELECT * FROM AMT_GeneralSettings WHERE InstanceID='Intel(r) AMT: General Settings'");
|
|
IManagedInstance generalSettingsInstance = generalSettingsRef.Get();
|
|
|
|
generalSettingsInstance.SetProperty("IdleWakeTimeout", value.ToString()); // Value can range from 1 to 65535);
|
|
|
|
generalSettingsRef.Put(generalSettingsInstance);
|
|
|
|
Console.WriteLine("Idle wake timeout was set successfully");
|
|
}
|
|
|
|
/// <summary>
|
|
/// Enumerate the current power packages
|
|
/// </summary>
|
|
public void enumerate()
|
|
{
|
|
Console.WriteLine("---------------Enumerate Power Packages--------------");
|
|
IManagedReference computerSystemRef = wsmanClient.NewReference("SELECT * FROM CIM_ComputerSystem WHERE Name='Intel(r) AMT'");
|
|
IManagedReference elementSettingDataRef = wsmanClient.NewReference("CIM_ElementSettingData");
|
|
|
|
elementSettingDataRef.AddSelector("ManagedElement", computerSystemRef);
|
|
|
|
//Traverse to the CIM_ElementSettingData instances that are connected to CIM_ComputerSystem.
|
|
foreach (IWsmanItem elementSettingDataItem in elementSettingDataRef.Enumerate("http://schemas.dmtf.org/wbem/wsman/1/wsman/SelectorFilter", null))
|
|
{
|
|
//For each instance, check if it is associated to the AMT_SystemPowerScheme instance.
|
|
if (elementSettingDataItem.Object.GetProperty("SettingData").IsA("AMT_SystemPowerScheme"))
|
|
{
|
|
// Get the AMT_systemPowerScheme object using its EPR.
|
|
IManagedInstance systemPowerSchemeInstance = elementSettingDataItem.Object.GetProperty("SettingData").Ref.Get();
|
|
IWsmanItem schemeGUID = systemPowerSchemeInstance.GetProperty("SchemeGUID");
|
|
IWsmanItem instanceID = systemPowerSchemeInstance.GetProperty("InstanceID");
|
|
IWsmanItem description = systemPowerSchemeInstance.GetProperty("Description");
|
|
|
|
Console.WriteLine("Instance ID: {0}", instanceID.ToString());
|
|
Console.WriteLine("GUID: {0}", schemeGUID.ToString());
|
|
Console.WriteLine("Description: {0}\n", description.ToString());
|
|
}
|
|
}
|
|
|
|
}
|
|
|
|
/// <summary>
|
|
/// Return the minimum time value, in minutes, that
|
|
/// Intel AMT will be operable after waking up from a
|
|
/// sleep power state. This timer value will be reloaded
|
|
/// whenever Intel AMT is servicing requests. Note: this
|
|
/// setting may not be applicable under some power package
|
|
/// definitions
|
|
/// </summary>
|
|
public IWsmanItem getIdleWakeTimeout()
|
|
{
|
|
Console.WriteLine("---------------Get Idle Wake Timeout--------------");
|
|
|
|
// Traversing the AMT_GeneralSettings instance using the Intel AMT as a reference.
|
|
IManagedReference generalSettingsRef = wsmanClient.NewReference("SELECT * FROM AMT_GeneralSettings WHERE InstanceID='Intel(r) AMT: General Settings'");
|
|
IManagedInstance generalSettingsInstance = generalSettingsRef.Get();
|
|
|
|
IWsmanItem IdleWakeTimeout = generalSettingsInstance.GetProperty("IdleWakeTimeout");
|
|
|
|
Console.WriteLine("Idle wake timeout: {0} minutes", IdleWakeTimeout.ToString());
|
|
return IdleWakeTimeout;
|
|
}
|
|
|
|
/// <summary>
|
|
/// The function will try to set the power package which
|
|
/// corresponds to the given schema GUID.
|
|
/// </summary>
|
|
/// <param name="guid">Power package GUID</param>
|
|
public void setPowerPackageBasedOnGuid(string schemaGuid)
|
|
{
|
|
Console.WriteLine("---------------Set Power Package Based on GUID--------------");
|
|
|
|
bool found = false;
|
|
|
|
|
|
IManagedReference computerSystemRef = wsmanClient.NewReference("SELECT * FROM CIM_ComputerSystem WHERE Name='Intel(r) AMT'");
|
|
IManagedReference elementSettingDataRef = wsmanClient.NewReference("CIM_ElementSettingData");
|
|
|
|
elementSettingDataRef.AddSelector("ManagedElement", computerSystemRef);
|
|
|
|
//Traverse to the CIM_ElementSettingData instances that are connected to CIM_ComputerSystem.
|
|
foreach (IWsmanItem elementSettingDataItem in elementSettingDataRef.Enumerate("http://schemas.dmtf.org/wbem/wsman/1/wsman/SelectorFilter", null))
|
|
{
|
|
//For each instance, check if it is associated to the AMT_SystemPowerScheme instance.
|
|
if (elementSettingDataItem.Object.GetProperty("SettingData").IsA("AMT_SystemPowerScheme"))
|
|
{
|
|
// Get the AMT_systemPowerScheme object using its EPR.
|
|
IManagedInstance systemPowerSchemeInstance = elementSettingDataItem.Object.GetProperty("SettingData").Ref.Get();
|
|
IWsmanItem schemeGUID = systemPowerSchemeInstance.GetProperty("SchemeGUID");
|
|
if (schemeGUID.ToString().CompareTo(schemaGuid) == 0)
|
|
{
|
|
//set the power scheme....
|
|
IManagedReference systemPowerSchemeRef = elementSettingDataItem.Object.GetProperty("SettingData").Ref;
|
|
IManagedInstance inputObject = systemPowerSchemeRef.CreateMethodInput("SetPowerScheme");
|
|
IManagedInstance outputObject = systemPowerSchemeRef.InvokeMethod(inputObject);
|
|
IWsmanItem returnValue = outputObject.GetProperty("ReturnValue");
|
|
|
|
if (returnValue.ToString().CompareTo("0") == 0)
|
|
{
|
|
//print the details of the power scheme
|
|
Console.WriteLine("Instance ID: {0}", systemPowerSchemeInstance.GetProperty("InstanceID").ToString());
|
|
Console.WriteLine("Description: {0}\n", systemPowerSchemeInstance.GetProperty("Description").ToString());
|
|
Console.WriteLine("GUID: {0}", schemeGUID.ToString());
|
|
|
|
found = true;
|
|
break;
|
|
}
|
|
}
|
|
}
|
|
}
|
|
|
|
if (!found)
|
|
{
|
|
Console.WriteLine("Error occurred in function setPowerPackageBasedOnGuid.");
|
|
throw new WsmanException("The given GUID has no corresponding Power Package.");
|
|
}
|
|
}
|
|
|
|
/// <summary>
|
|
/// Find the current active power schema using enumerate with filter.
|
|
/// Note:
|
|
/// It is possible to iterate all the instances of CIM_ElementSettingData
|
|
/// and to check each one of them if it is connected to CIM_ComputerSystem
|
|
/// and to AMT_SystemPowerScheme and then check if the IsCurrent field
|
|
/// of the CIM_ElementSettingData is equal to 1. Doing it this way might
|
|
/// be easier but less efficient since there might be a lot of
|
|
/// CIM_ElementSettingData instances.
|
|
/// </summary>
|
|
public IManagedInstance getActivePowerSchema()
|
|
{
|
|
Console.WriteLine("---------------Get Current Active Power Package --------------");
|
|
//Not required to check for the firmware version as in the old Sample.
|
|
|
|
IManagedReference computerSystemRef = wsmanClient.NewReference("SELECT * FROM CIM_ComputerSystem WHERE Name='Intel(r) AMT'");
|
|
IManagedReference elementSettingDataRef = wsmanClient.NewReference("CIM_ElementSettingData");
|
|
|
|
elementSettingDataRef.AddSelector("ManagedElement", computerSystemRef);
|
|
|
|
//Traverse to the CIM_ElementSettingData instances that are connected to CIM_ComputerSystem.
|
|
foreach (IWsmanItem elementSettingDataItem in elementSettingDataRef.Enumerate("http://schemas.dmtf.org/wbem/wsman/1/wsman/SelectorFilter", null))
|
|
{
|
|
IWsmanItem isCurrent = elementSettingDataItem.Object.GetProperty("IsCurrent");
|
|
if (isCurrent.ToString() == "0" || isCurrent.ToString() == "2")
|
|
{
|
|
continue;
|
|
}
|
|
|
|
if (isCurrent.ToString() == "1")
|
|
{
|
|
//For each instance, check if it is associated to the AMT_SystemPowerScheme instance.
|
|
if (elementSettingDataItem.Object.GetProperty("SettingData").IsA("AMT_SystemPowerScheme"))
|
|
{
|
|
// Get the AMT_systemPowerScheme object using its EPR.
|
|
IManagedInstance systemPowerSchemeInstance = elementSettingDataItem.Object.GetProperty("SettingData").Ref.Get();
|
|
IWsmanItem schemeGUID = systemPowerSchemeInstance.GetProperty("SchemeGUID");
|
|
IWsmanItem instanceID = systemPowerSchemeInstance.GetProperty("InstanceID");
|
|
IWsmanItem description = systemPowerSchemeInstance.GetProperty("Description");
|
|
|
|
Console.WriteLine("Instance ID: {0}", instanceID.ToString());
|
|
Console.WriteLine("GUID: {0}", schemeGUID.ToString());
|
|
Console.WriteLine("Description: {0}", description.ToString());
|
|
|
|
return systemPowerSchemeInstance;
|
|
}
|
|
}
|
|
}
|
|
return null;
|
|
|
|
// else{}
|
|
|
|
}
|
|
|
|
#endregion PUBLIC_FUNCTION
|
|
}
|
|
}
|