65 lines
2.9 KiB
Plaintext

// Copyright (c) 2008 DMTF. All rights reserved.
[Association, Version ( "2.19.1" ),
UMLPackagePath ( "CIM::Core::Settings" ),
Description (
"ElementSettingData represents the association between "
"ManagedElements and applicable setting data. This association "
"also describes whether this is a default or current setting." )]
class CIM_ElementSettingData {
[Key, Description ( "The managed element." )]
CIM_ManagedElement REF ManagedElement;
[Key, Description (
"The SettingData object associated with the element." )]
CIM_SettingData REF SettingData;
[Description (
"An enumerated integer indicating that the referenced "
"setting is a default setting for the element, or that "
"this information is unknown." ),
ValueMap { "0", "1", "2" },
Values { "Unknown", "Is Default", "Is Not Default" }]
uint16 IsDefault;
[Description (
"An enumerated integer indicating that the referenced "
"setting is currently being used in the operation of the "
"element, or that this information is unknown." ),
ValueMap { "0", "1", "2" },
Values { "Unknown", "Is Current", "Is Not Current" }]
uint16 IsCurrent;
[Description (
"An enumerated integer indicating whether or not the "
"referenced setting is the next setting to be applied. "
"For example, the application could take place on a "
"re-initialization, reset, reconfiguration request. This "
"could be a permanent setting, or a setting used only one "
"time, as indicated by the flag. If it is a permanent "
"setting then the setting is applied every time the "
"managed element reinitializes, until this flag is "
"manually reset. However, if it is single use, then the "
"flag is automatically cleared after the settings are "
"applied. Also note that if this flag is specified (i.e. "
"set to value other than \"Unknown\"), then this takes "
"precedence over any SettingData that may have been "
"specified as Default. For example: If the managed "
"element is a computer system, and the value of this flag "
"is \"Is Next\", then the setting will be effective next "
"time the system resets. And, unless this flag is "
"changed, it will persist for subsequent system resets. "
"However, if this flag is set to \"Is Next For Single "
"Use\", then this setting will only be used once and the "
"flag would be reset after that to \"Is Not Next\". So, "
"in the above example, if the system reboots in a quick "
"succession, the setting will not be used at the second "
"reboot." ),
ValueMap { "0", "1", "2", "3" },
Values { "Unknown", "Is Next", "Is Not Next",
"Is Next For Single Use" }]
uint16 IsNext;
};