154 lines
5.9 KiB
Plaintext

#--------------------------------------------------------------------
#
# Copyright (C) 2003 Intel Corporation
#
# Managment Presence Server configuration file
#
#--------------------------------------------------------------------
# Configuration file instructions
# -------------------------------
# Use whitespace (tabs and spaces) freely.
# String to the left of the equal sign can be delimited with double quotes.
# The structure of the config file is in sections indicated by squared
# brackets.
# All the fields between one section and another belong to the first section.
# Before each section, a description of all its possible fields appear.
# Fields not indicated by '(OPTIONAL)' must appear under their section, and
# fields indicated by '(OPTIONAL)' are optional, and their default value is
# indicated to right of the equal sign.
# A field which is commented out under a section means that the value given to
# the field in the comment is the default value given to the field.
# This value may be uncommented for immediate use.
# *** [Network] section description ***
# AMTListenIP (IP/FQDN) - IP/FQDN that MPS listens to for new Intel AMT
# connection requests.
# AMTListenPort (unsigned short) - port that MPS listens to for new Intel AMT
# connection requests.
# SocksListenIP (IP/FQDN) - IP/FQDN address that MPS listens to for new SOCKS
# connection requests.
# SocksListenPort (unsigned short) - port that MPS listens to for new SOCKS
# connection requests.
# (OPTIONAL) HttpListenIP (unsigned short) = 10.212.212.80 - IP/FQDN address
# that MPS listens to for new HTTP connection requests.
# HttpListenPort (unsigned short) - port that MPS listens to for new HTTP
# connection requests.
# (OPTIONAL) SOAPListenIP (IP/FQDN) = 10.212.212.80 - IP/FQDN address that MPS
# listens to for new SOAP connection requests.
# (OPTIONAL) SOAPListenPort (unsigned short) = 7793 - port that MPS listens to
# for new SOAP connection requests.
[Network]
AMTListenIP = 10.212.212.80
AMTListenPort = 16982
HttpListenIP = 10.212.212.80
HttpListenPort = 8080
SocksListenIP = 10.212.212.80
SocksListenPort = 8090
SOAPListenIP = 10.212.212.80
SOAPListenPort = 7793
# *** [Logger] section description ***
# (OPTIONAL) LogFilePath (string) = "logs/" - path in which the log file is
# created.
# (OPTIONAL) LogFileName (string) = "mps.log" - name of the log file.
# (OPTIONAL) LogFileMaxSize (unsigned int) = 1000 - maximum size of a single
# log file (in kB), beyond which another log file is created.
# (OPTIONAL) LogFileMaxFiles (unsigned int) = 100 - maximum number of log files
# to create, beyond which older log files will be overwritten.
[Logger]
LogFilePath = "logs/"
LogFileName = "mps.log"
LogFileMaxSize = 10000
LogFileMaxFiles = 10
# *** [AMT_Authenticate] section description ***
# NeedAuthentication (boolean) - parameter specifying if connection
# authentication data is needed for AMT connection.
# Next elements in section are needed only if NeedAuthentication was set as
# true.
# (OPTIONAL) DllName (string) - the full path name of the dll file to be used
# to gain the said authentication.
# (OPTIONAL) DllParameters (string) - Parameters to pass to the dll.
[AMT_Authenticate]
NeedAuthentication = false
# DllName =
# DllParameters =
# *** [Socks_Authenticate] section description ***
# NeedAuthentication (boolean) - parameter specifying if connection
# authentication data is needed for Socks connection.
# Next elements in section are needed only if NeedAuthentication was set as
# true.
# (OPTIONAL) DllName (string) - the full path name of the dll file to be used
# to gain the said authentication.
# (OPTIONAL) DllParameters (string) - Parameters to pass to the dll.
[Socks_Authenticate]
NeedAuthentication = false
# DllName =
# DllParameters =
# *** [Notification_Authentication] section description ***
# NeedNotificationAuthentication (boolean) - indicates if authentication is
# needed when notifying managment consoles of new AMT tunnels.
# Next elements in section are needed only if NeedNotificationAuthentication
# was set as true.
# (OPTIONAL) Username (string) = user - the username for the notification's
# authentication.
# (OPTIONAL) Password (string) = pass - the password for the notification's
# authentication.
[Notification_Authentication]
NeedNotificationAuthentication = false
# Username = user
# Password = pass
# *** [Filtering] section description ***
# FilterUnauthorizedServers (boolean) - indicates if the authorized servers
# list should be used. If not, then direct connection and UDP message are
# always forwarded.
[Filtering]
FilterUnauthorizedServers = false
# *** [SOAP_Authentication] section description ***
# *** NOT SUPPORTED IN LINUX ***
# NeedAuthentication (boolean) - parameter specifying if connection
# authentication data is needed for SOAP connection.
# Next elements in section are needed only if NeedAuthentication was set as
# true.
# (OPTIONAL) DllName (string) - the full path name of the dll file to be used
# to gain the said authentication.
# (OPTIONAL) DllParameters (string) - Parameters to pass to the dll.
[SOAP_Authentication]
NeedAuthentication = false
# DllName =
# DllParameters =
# *** [Management_Interface] section description ***
# MaxEnumElements (int) - The maximum number of elements that will be sent in a
# response to a Pull request.
# EnumCtxTimeout (int) - The duration of the validity of an enumeration context
# in seconds.
# MaxConcurrentEnums (int) - The number of concurrent enumerations that are
# allowed.
# MaxSubscribers (int) - The maximum number of subscribers that are allowed.
[Management_Interface]
#MaxEnumElements = 50
#EnumCtxTimeout = 500
#MaxConcurrentEnums = 10
#MaxSubscribers = 30