#-------------------------------------------------------------------- # # Copyright (C) 2003 Intel Corporation # # Managment Presence Server configuration file # #-------------------------------------------------------------------- # Configuration file instructions # ------------------------------- # Use whitespace (tabs and spaces) freely. # String to the left of the equal sign can be delimited with double quotes. # The structure of the config file is in sections indicated by squared # brackets. # All the fields between one section and another belong to the first section. # Before each section, a description of all its possible fields appear. # Fields not indicated by '(OPTIONAL)' must appear under their section, and # fields indicated by '(OPTIONAL)' are optional, and their default value is # indicated to right of the equal sign. # A field which is commented out under a section means that the value given to # the field in the comment is the default value given to the field. # This value may be uncommented for immediate use. # *** [Network] section description *** # AMTListenIP (IP/FQDN) - IP/FQDN that MPS listens to for new Intel AMT # connection requests. # AMTListenPort (unsigned short) - port that MPS listens to for new Intel AMT # connection requests. # SocksListenIP (IP/FQDN) - IP/FQDN address that MPS listens to for new SOCKS # connection requests. # SocksListenPort (unsigned short) - port that MPS listens to for new SOCKS # connection requests. # (OPTIONAL) HttpListenIP (unsigned short) = 10.212.212.80 - IP/FQDN address # that MPS listens to for new HTTP connection requests. # HttpListenPort (unsigned short) - port that MPS listens to for new HTTP # connection requests. # (OPTIONAL) SOAPListenIP (IP/FQDN) = 10.212.212.80 - IP/FQDN address that MPS # listens to for new SOAP connection requests. # (OPTIONAL) SOAPListenPort (unsigned short) = 7793 - port that MPS listens to # for new SOAP connection requests. [Network] AMTListenIP = 10.212.212.80 AMTListenPort = 16982 HttpListenIP = 10.212.212.80 HttpListenPort = 8080 SocksListenIP = 10.212.212.80 SocksListenPort = 8090 SOAPListenIP = 10.212.212.80 SOAPListenPort = 7793 # *** [Logger] section description *** # (OPTIONAL) LogFilePath (string) = "logs/" - path in which the log file is # created. # (OPTIONAL) LogFileName (string) = "mps.log" - name of the log file. # (OPTIONAL) LogFileMaxSize (unsigned int) = 1000 - maximum size of a single # log file (in kB), beyond which another log file is created. # (OPTIONAL) LogFileMaxFiles (unsigned int) = 100 - maximum number of log files # to create, beyond which older log files will be overwritten. [Logger] LogFilePath = "logs/" LogFileName = "mps.log" LogFileMaxSize = 10000 LogFileMaxFiles = 10 # *** [AMT_Authenticate] section description *** # NeedAuthentication (boolean) - parameter specifying if connection # authentication data is needed for AMT connection. # Next elements in section are needed only if NeedAuthentication was set as # true. # (OPTIONAL) DllName (string) - the full path name of the dll file to be used # to gain the said authentication. # (OPTIONAL) DllParameters (string) - Parameters to pass to the dll. [AMT_Authenticate] NeedAuthentication = false # DllName = # DllParameters = # *** [Socks_Authenticate] section description *** # NeedAuthentication (boolean) - parameter specifying if connection # authentication data is needed for Socks connection. # Next elements in section are needed only if NeedAuthentication was set as # true. # (OPTIONAL) DllName (string) - the full path name of the dll file to be used # to gain the said authentication. # (OPTIONAL) DllParameters (string) - Parameters to pass to the dll. [Socks_Authenticate] NeedAuthentication = false # DllName = # DllParameters = # *** [Notification_Authentication] section description *** # NeedNotificationAuthentication (boolean) - indicates if authentication is # needed when notifying managment consoles of new AMT tunnels. # Next elements in section are needed only if NeedNotificationAuthentication # was set as true. # (OPTIONAL) Username (string) = user - the username for the notification's # authentication. # (OPTIONAL) Password (string) = pass - the password for the notification's # authentication. [Notification_Authentication] NeedNotificationAuthentication = false # Username = user # Password = pass # *** [Filtering] section description *** # FilterUnauthorizedServers (boolean) - indicates if the authorized servers # list should be used. If not, then direct connection and UDP message are # always forwarded. [Filtering] FilterUnauthorizedServers = false # *** [SOAP_Authentication] section description *** # *** NOT SUPPORTED IN LINUX *** # NeedAuthentication (boolean) - parameter specifying if connection # authentication data is needed for SOAP connection. # Next elements in section are needed only if NeedAuthentication was set as # true. # (OPTIONAL) DllName (string) - the full path name of the dll file to be used # to gain the said authentication. # (OPTIONAL) DllParameters (string) - Parameters to pass to the dll. [SOAP_Authentication] NeedAuthentication = false # DllName = # DllParameters = # *** [Management_Interface] section description *** # MaxEnumElements (int) - The maximum number of elements that will be sent in a # response to a Pull request. # EnumCtxTimeout (int) - The duration of the validity of an enumeration context # in seconds. # MaxConcurrentEnums (int) - The number of concurrent enumerations that are # allowed. # MaxSubscribers (int) - The maximum number of subscribers that are allowed. [Management_Interface] #MaxEnumElements = 50 #EnumCtxTimeout = 500 #MaxConcurrentEnums = 10 #MaxSubscribers = 30