- 修复RouteService中错误过滤home路由的问题 - 后端现在正确返回所有用户有权限的路由 - 添加设备管理相关功能(列表、在线监控、电源管理、远程监控) - 添加详细的修复文档和重启脚本 - 更新权限配置脚本 问题根源:后端代码中有逻辑会过滤掉home路由,导致前端收到空数组,无法生成菜单 解决方案:移除过滤home路由的逻辑,让后端返回所有有权限的路由
23 lines
1.3 KiB
PowerShell
23 lines
1.3 KiB
PowerShell
$schemeGUID = # The giud of the powerpackage you want to activate.
|
|
# Create a reference to the CIM_ComputerSystem instance.
|
|
$computerSystemRef = $wsmanConnectionObject.NewReference("SELECT * FROM CIM_ComputerSystem WHERE Name='Intel(r) AMT'")
|
|
$elementSettingsDataRef = $wsmanConnectionObject.NewReference("CIM_ElementSettingData")
|
|
$elementSettingsDataRef.AddSelector("ManagedElement", $computerSystemRef)
|
|
# Traverse to the CIM_ElementSettingData instances that are connected to CIM_ComputerSystem.
|
|
foreach($elementSettingDataItem in $elementSettingsDataRef.Enumerate("http://schemas.dmtf.org/wbem/wsman/1/wsman/SelectorFilter", $null))
|
|
{
|
|
# For each instance, check if it is associated to the AMT_SystemPowerScheme instance.
|
|
if($elementSettingDataItem.Object.GetProperty("SettingData").IsA("AMT_SystemPowerScheme"))
|
|
{
|
|
$systemPowerSchemeInstance = $elementSettingDataItem.Object.GetProperty("SettingData").Ref.Get()
|
|
if($systemPowerSchemeInstance.GetProperty("SchemeGUID") -like $schemeGUID)
|
|
{
|
|
# Get the AMT_systemPowerScheme object using its EPR.
|
|
$systemPowerSchemeRef = $elementSettingDataItem.Object.GetProperty("SettingData").Ref
|
|
$inputObject = $systemPowerSchemeRef.CreateMethodInput("SetPowerScheme")
|
|
$outputObject = $systemPowerSchemeRef.InvokeMethod($inputObject)
|
|
$returnValue = $outputObject.GetProperty("ReturnValue")
|
|
break
|
|
}
|
|
}
|
|
} |